Generating standardized image data for testing and calibrating quantification of volumes, surfaces, lengths, and object counts in fibrous and porous materials using X ‐ray microtomography
Abstract Quantification of the structure and composition of biomaterials using micro‐CT requires image segmentation due to the low contrast and overlapping radioopacity of biological materials. The amount of bias introduced by segmentation procedures is generally unknown. We aim to develop software that generates three‐dimensional models of fibrous and porous structures with known volumes, surfaces, lengths, and object counts in fibrous materials and to provide a software tool that calibrates quantitative micro‐CT assessments. Virtual image stacks were generated using the newly developed software TeIGen, enabling the...
Source: Microscopy Research and Technique - February 24, 2018 Category: Laboratory Medicine Authors: Miroslav Ji řík, Martin Bartoš, Petr Tomášek, Anna Malečková, Tomáš Kural, Jana Horáková, David Lukáš, Tomáš Suchý, Petra Kochová, Marie Hubálek Kalbáčová, Milena Králíčková, Zbyněk Tonar Tags: RESEARCH ARTICLE Source Type: research

Generating standardized image data for testing and calibrating quantification of volumes, surfaces, lengths, and object counts in fibrous and porous materials using X ‐ray microtomography
Microscopy Research and Technique, EarlyView. (Source: Microscopy Research and Technique)
Source: Microscopy Research and Technique - February 24, 2018 Category: Laboratory Medicine Source Type: research

---
Microscopy Research and Technique, Ahead of Print. (Source: Microscopy Research and Technique)
Source: Microscopy Research and Technique - February 24, 2018 Category: Laboratory Medicine Source Type: research

Label ‐free monitoring of inflammatory tissue conditions using a carrageenan‐induced acute inflammation rat model
In this study, we evaluate the feasibility of Raman spectroscopy as a new, easy, fast, and accurate diagnostic method to support diagnostic decisions. The molecular changes in carrageenan‐induced acute inflammation rat tissues were assessed by Raman spectroscopy. Volumes of 0 (control), 100, 150, and 200 µL of 1% carrageenan were administered to rat hind paws to control the degree of inflammation. The prominent peaks at [1,062, 1,131] cm−1 and [2,847, 2,881] cm−1 were selected as characteristic measurements corresponding to the C–C stretching vibrational modes and the symmetric and asymmetric C–H (CH2) stretchin...
Source: Microscopy Research and Technique - February 23, 2018 Category: Laboratory Medicine Authors: Seung Ho Lee, Sang Hwa Lee, Jae ‐Ho Shin, Samjin Choi Tags: RESEARCH ARTICLE Source Type: research

Label ‐free monitoring of inflammatory tissue conditions using a carrageenan‐induced acute inflammation rat model
Microscopy Research and Technique, EarlyView. (Source: Microscopy Research and Technique)
Source: Microscopy Research and Technique - February 23, 2018 Category: Laboratory Medicine Source Type: research

---
Microscopy Research and Technique, Ahead of Print. (Source: Microscopy Research and Technique)
Source: Microscopy Research and Technique - February 23, 2018 Category: Laboratory Medicine Source Type: research

High resolution SEM characterization of nano ‐precipitates in ODS steels
Abstract The performance of the present‐day scanning electron microscopy (SEM) extends far beyond delivering electronic images of the surface topography. Oxide dispersion strengthened (ODS) steel is on of the most promising materials for the future nuclear fusion reactor because of its good radiation resistance, and higher operation temperature up to 750°C. The microstructure of ODS should not exceed tens of nm, therefore there is a strong need in a fast and reliable technique for their characterization. In this work, the results of low‐kV SEM characterization of nanoprecipitates formed in the ODS matrix are presented...
Source: Microscopy Research and Technique - February 21, 2018 Category: Laboratory Medicine Authors: Iwona J óźwik, Agata Strojny‐Nędza, Marcin Chmielewski, Katarzyna Pietrzak, Łukasz Kurpaska, Szymon Nosewicz Tags: RESEARCH ARTICLE Source Type: research

High resolution SEM characterization of nano ‐precipitates in ODS steels
Microscopy Research and Technique, EarlyView. (Source: Microscopy Research and Technique)
Source: Microscopy Research and Technique - February 21, 2018 Category: Laboratory Medicine Source Type: research

Evaluation of electron tomography reconstruction methods for interface roughness measurement
Microscopy Research and Technique, EarlyView. (Source: Microscopy Research and Technique)
Source: Microscopy Research and Technique - February 21, 2018 Category: Laboratory Medicine Source Type: research

An improved strategy for skin lesion detection and classification using uniform segmentation and feature selection based approach
Microscopy Research and Technique, EarlyView. (Source: Microscopy Research and Technique)
Source: Microscopy Research and Technique - February 21, 2018 Category: Laboratory Medicine Source Type: research

---
Microscopy Research and Technique, Ahead of Print. (Source: Microscopy Research and Technique)
Source: Microscopy Research and Technique - February 21, 2018 Category: Laboratory Medicine Source Type: research

---
Microscopy Research and Technique,Volume 81, Issue 3, Page C1-C1, March 2018. (Source: Microscopy Research and Technique)
Source: Microscopy Research and Technique - February 21, 2018 Category: Laboratory Medicine Source Type: research