---
Ophthalmic and Physiological Optics, Ahead of Print. (Source: Ophthalmic and Physiological Optics)
Source: Ophthalmic and Physiological Optics - January 31, 2018 Category: Opthalmology Source Type: research

Foveal vision power errors induced by spectacle lenses designed to correct peripheral refractive errors
Ophthalmic and Physiological Optics, EarlyView. (Source: Ophthalmic and Physiological Optics)
Source: Ophthalmic and Physiological Optics - January 30, 2018 Category: Opthalmology Source Type: research

Analysing the impact of myopia on the Stiles ‐Crawford effect of the first kind using a digital micromirror device
Ophthalmic and Physiological Optics, EarlyView. (Source: Ophthalmic and Physiological Optics)
Source: Ophthalmic and Physiological Optics - January 30, 2018 Category: Opthalmology Source Type: research

---
Ophthalmic and Physiological Optics, Ahead of Print. (Source: Ophthalmic and Physiological Optics)
Source: Ophthalmic and Physiological Optics - January 30, 2018 Category: Opthalmology Source Type: research

Analysing the impact of myopia on the Stiles ‐Crawford effect of the first kind using a digital micromirror device
ConclusionThe study confirms a clear link between SCE‐I directionality, uncorrected defocus, and axial eye length. This may play a role for emmetropization and thus myopic progression as cone photoreceptors capture light from a wider pupil area in elongated eyes due to a geometrical scaling. (Source: Ophthalmic and Physiological Optics)
Source: Ophthalmic and Physiological Optics - January 30, 2018 Category: Opthalmology Authors: Alessandra Carmichael Martins, Brian Vohnsen Tags: Feature Issue Article Source Type: research

Optical treatment of amblyopia in older children and adults is essential prior to enrolment in a clinical trial
Ophthalmic and Physiological Optics,Volume 38, Issue 2, Page 129-143, March 2018. (Source: Ophthalmic and Physiological Optics)
Source: Ophthalmic and Physiological Optics - January 22, 2018 Category: Opthalmology Source Type: research

---
Ophthalmic and Physiological Optics,Volume 38, Issue 2, Page 129-143, March 2018. (Source: Ophthalmic and Physiological Optics)
Source: Ophthalmic and Physiological Optics - January 22, 2018 Category: Opthalmology Source Type: research

Detecting glaucomatous progression with infrequent visual field testing
Ophthalmic and Physiological Optics,Volume 38, Issue 2, Page 174-182, March 2018. (Source: Ophthalmic and Physiological Optics)
Source: Ophthalmic and Physiological Optics - January 8, 2018 Category: Opthalmology Source Type: research

Experimental investigation of accommodation in eyes fit with multifocal contact lenses using a clinical auto ‐refractor
Ophthalmic and Physiological Optics,Volume 38, Issue 2, Page 152-163, March 2018. (Source: Ophthalmic and Physiological Optics)
Source: Ophthalmic and Physiological Optics - January 8, 2018 Category: Opthalmology Source Type: research

A basis for customising perimetric locations within the macula in glaucoma
Ophthalmic and Physiological Optics,Volume 38, Issue 2, Page 164-173, March 2018. (Source: Ophthalmic and Physiological Optics)
Source: Ophthalmic and Physiological Optics - January 8, 2018 Category: Opthalmology Source Type: research

---
Ophthalmic and Physiological Optics,Volume 38, Issue 2, Page 174-182, March 2018. (Source: Ophthalmic and Physiological Optics)
Source: Ophthalmic and Physiological Optics - January 8, 2018 Category: Opthalmology Source Type: research

---
Ophthalmic and Physiological Optics,Volume 38, Issue 2, Page 152-163, March 2018. (Source: Ophthalmic and Physiological Optics)
Source: Ophthalmic and Physiological Optics - January 8, 2018 Category: Opthalmology Source Type: research

---
Ophthalmic and Physiological Optics,Volume 38, Issue 2, Page 164-173, March 2018. (Source: Ophthalmic and Physiological Optics)
Source: Ophthalmic and Physiological Optics - January 8, 2018 Category: Opthalmology Source Type: research

Experimental investigation of accommodation in eyes fit with multifocal contact lenses using a clinical auto ‐refractor
ConclusionsWith consistent sampling at the same pupil location, the open field Grand Seiko clinical autorefractor proved an effective tool for assessing the on‐axis refractive state and accommodative responses of eyes fit with multi‐zone bifocal and multifocal CLs. (Source: Ophthalmic and Physiological Optics)
Source: Ophthalmic and Physiological Optics - January 8, 2018 Category: Opthalmology Authors: Basal H. Altoaimi, Pete Kollbaum, Dawn Meyer, Arthur Bradley Tags: Original Article Source Type: research