Three auditory brainstem response (ABR) methods tested and compared in two anuran species [RESEARCH ARTICLE]

In conclusion, the mABR method gave the most sensitive audiograms. The tABR method showed a similar audiogram when using relatively long-duration tone bursts (25 ms). The ltABR method is not a good choice for studying hearing thresholds above 1000 Hz because of the bias introduced by spike rate saturation in the nerve fibers and their inability to phase lock.
Source: Journal of Experimental Biology - Category: Biology Authors: Tags: RESEARCH ARTICLE Source Type: research