Use of automated quantitative pupillometric evaluation for monitoring the severity of diabetic retinopathy

Conclusion: This study revealed that the measurements derived from automated pupillometry are altered in patients with type 2 diabetes mellitus. The presence of nonproliferative diabetic retinopathy does not have a negative effect on pupillometry findings, but with proliferative diabetic retinopathy, significant alterations were observed. These results suggest that using automated quantitative pupillometry may be useful in verifying the severity of diabetic retinopathy.RESUMO Objetivos: Procuramos avaliar o uso da pupilometria est ática e dinâmica quantitativa automatizada na triagem de pacientes com diabetes mellitus tipo 2 e em di­ferentes estágios de retinopatia diabética. Métodos: Cento e cinquenta e cinco pacientes com diabetes mellitus tipo 2 (grupo com diabetes mellitus) foram incluídos neste estudo e outros 14 5 controles saudáveis pareados por idade e sexo para server como grupo controle. O grupo com diabetes mellitus foi dividido em três subgrupos: diabetes mellitus sem retinopatia diabética (retinopatia não diabética), retinopatia diabética não proliferativa e retinopatia diabética proliferativ a. A pupilometria estática e dinâmica foi realizada utilizando uma camera rotative Scheimpflug com um sistema baseado em topografia. Resultados: Em termos de diâmetro da pupila, tanto na pupilometria estática quanto na dinâmica (p<0,05), foram observadas diferen ças estatisticamente significantes entre os grupos diabetes mellitus e controle e tambÃ...
Source: Arquivos Brasileiros de Oftalmologia - Category: Opthalmology Source Type: research