Interobserver variability of ventilatory anaerobic threshold in asymptomatic volunteers

ConclusionsExperienced physicians show high agreement when determining AT in asymptomatic volunteers. However, agreement between physicians and qualified medical assistants is lower, and there is substantial deviation in AT determination between physicians or medical assistants and software-based algorithms. This must be considered when using AT as a decision tool.
Source: Multidisciplinary Respiratory Medicine - Category: Respiratory Medicine Source Type: research