Comparative life-cycle cost and GHG emission analysis of five different water heating systems for residential buildings in Australia

Publication date: Available online 1 December 2018Source: Beni-Suef University Journal of Basic and Applied SciencesAuthor(s): Nallapaneni Manoj Kumar, Mobi MathewAbstractIn this paper, five different types of water heating systems namely electric instantaneous, electric storage, natural gas instantaneous, natural gas storage, and heat pump are studied for Australian conditions. The study is carried out for understanding the life cycle cost of each system under similar water demand conditions. Focus is made on life-cycle cost (LCC) that include the running costs on an annual basis, and total running cost for the system life, maintenance cost; and greenhouse gas (GHG) emissions. The observations reveal that five systems had major differences in the upfront cost, running cost, and life-cycle cost, and GHG emissions. The observed LCC and GHG emissions for electric instantaneous, electric storage, natural gas instantaneous, natural gas storage, and heat pump are 9005 AU$, 12,724 AU$, 6955 AU$, 7479 AU$, and 8098 AU$, and 1862 tons of CO2, 2306 tons of CO2, 851 tons of CO2, 917 tons of CO2, and 842 tons of CO2 respectively.
Source: Beni Suef University Journal of Basic and Applied Sciences - Category: Science Source Type: research