Development and validation of LC-MS/MS assay for the determination of Butoconazole in human plasma: Evaluation of systemic absorption following topical application in healthy volunteers

Publication date: December 2017Source: Bulletin of Faculty of Pharmacy, Cairo University, Volume 55, Issue 2Author(s): Eman G. Nouman, Medhat A. Al-Ghobashy, Hayam M. LotfyAbstractButoconazole is an imidazole antifungal that is more effective than miconazole and clotrimazole for treatment of vaginal candidiasis. A highly sensitive tandem mass spectrometric assay was developed and validated to evaluate systemic absorption of Butoconazole following intravaginal administration. Chromatographic separation was achieved using Waters Xterra C18 column (3 µm, 3.0 × 50.0 mm). Liquid-liquid extraction using tert-butyl methyl ether was used for preparation of plasma samples. The mobile phase was solvent A: 0.1% formic acid in water and solvent B: acetonitrile: methanol (30:70, v/v), using gradient elution mode at 0.5 mL/min. Detection at positive electrospray ionization in the MRM mode was then employed. Analysis was carried out within 5.5 min over a linear concentration range of 0.10–30.00 ng/mL. Validation was carried out according to US FDA guidelines for bioanalytical method validation. Matrix effect, recovery efficiency and process efficiency have been investigated for the analyte and internal standard in neat solvent, post-extraction matrix and plasma. The mean percentage recoveries were higher than 80%, the accuracy was 93.51–106.85% and the RSD was below 10% throughout the studied concentration range. Results indicated sufficient stabilit...
Source: Bulletin of Faculty of Pharmacy, Cairo University - Category: Drugs & Pharmacology Source Type: research