Motion-sensitized SPRITE measurements of hydrodynamic cavitation in fast pipe flow

The pressure variations experienced by a liquid flowing through a pipe constriction can, in some cases, result in the formation of a bubble cloud (i.e., hydrodynamic cavitation). Due to the nature of the bubble cloud, it is ideally measured through the use of non-optical and non-invasive techniques; therefore, it is well-suited for study by magnetic resonance imaging. This paper demonstrates the use of Conical SPRITE (a 3D, centric-scan, pure phase-encoding pulse sequence) to acquire time-averaged void fraction and velocity information about hydrodynamic cavitation for water flowing through a pipe constriction.
Source: Magnetic Resonance Imaging - Category: Radiology Authors: Source Type: research
More News: MRI Scan | PET Scan | Radiology | Study