Early loading of maxillary titanium implants with a nanostructured calcium-incorporated surface (Xpeed): 5-year results from a multicentre randomised controlled trial.

CONCLUSIONS: Both implant surfaces provided good clinical results and no significant difference was found when comparing titanium implants with a nanostructured calcium-incorporated surface with implants with an RBM surface. Conflict-of-interest statement: MegaGen partially supported this trial and donated the implants and prosthetic components. The study design was negotiated with MegaGen Implant Co, Gyeongbuk, South Korea, however, data property belonged to the authors and by no means did MegaGen interfere with the conduct of the trial or the publication of its results. PMID: 29234748 [PubMed - in process]