Conclusions Different mechanisms underlie early and late ScT: although incomplete BRS deployment was a predictor of the former, the latter was associated with large vessel size and BRS undersizing. However, both phenomena are significantly less frequent with an optimized implantation technique. (Mainz Intracoronary Database. The Coronary Slow-flow and Microvascular Diseases Registry [MICAT]; NCT02180178)