Diagnostic performance of commercial serological assays measuring Bordetella pertussis IgG antibodies

Due to their specificity to B. pertussis antigens, immunoglobulin G (IgG) antibodies should be measured primarily for diagnosing pertussis. We compared the diagnostic performance of commercially available enzyme-linked immunosorbent assays (ELISAs) and chemiluminescent immunoassays (CLIAs) measuring IgG to B. pertussis antigens. An in-house ELISA with purified pertussis toxin (PT) was used as reference system. Commercial assays using PT only as coating antigen showed better performance as compared to those using a mixture of different antigens.
Source: Diagnostic Microbiology and Infectious Disease - Category: Microbiology Authors: Source Type: research