Is there evidence for more than two diffusion components in abdominal organs? – A magnetic resonance imaging study in healthy volunteers

In this study, we assessed the ground truth of underlying diffusion components in healthy abdominal organs using an extensive DWI protocol and subsequent computation of apparent diffusion coefficient ‘spectra’, similar to the computation of previously described T2 relaxation spectra. Diffusion datasets of eight healthy subjects were acquired in a 3‐T magnetic resonance scanner using 68 different b values during free breathing (equidistantly placed in the range 0–1005 s/mm2). Signal intensity curves as a function of the b value were analyzed in liver, spleen and kidneys using non‐negative least‐squares fitting to a distribution of decaying exponential functions with minimum amplitude energy regularization. In all assessed organs, the typical slow‐ and fast‐diffusing components of the IVIM model were detected [liver: true diffusion D = (1.26 ± 0.01) × 10–3 mm2/s, pseudodiffusion D* = (270 ± 44) × 10–3 mm2/s; kidney cortex: D = (2.26 ± 0.07) × 10–3 mm2/s, D* = (264 ± 78) × 10–3 mm2/s; kidney medulla: D = (1.57 ± 0.28) × 10–3 mm2/s, D* = (168 ± 18) × 10–3 mm2/s; spleen: D = (0.91 ± 0.01) × 10–3 mm2/s, D* = (69.8 ± 0.50) × 10–3 mm2/s]. However, in the liver and kidney, a third component between D and D* was found [liver: D′ = (43.8 ± 5.9) × 10–3 mm2/s; kidney cortex: D′ = (23.8 ± 11.5) × 10–3 mm2/s; kidney medulla: D′ = (5.23 ± 0.93) × 10–3 mm2/s], whereas no third component was detected in the spleen. Fitting with ...