Static and dynamic liver stiffness: An ex vivo porcine liver study using MR elastography

Magnetic resonance elastography (MRE) is an MRI-based noninvasive technique for quantitatively assessing tissue stiffness. The hypothesis of this study is that stiffness increases with portal pressure. We further hypothesized that the rate of stiffness change with pressure would be larger in liver tissue treated to simulate the stiffening effects of fibrosis. In agreement with our hypothesis, the formalin-treated livers were stiffer than the untreated livers, and in both groups the liver stiffness increased with portal venous pressure.
Source: Magnetic Resonance Imaging - Category: Radiology Authors: Tags: Original contribution Source Type: research