In Situ Splitting of a Rib Bone Graft for Reconstruction of Orbital Floor and Medial Wall

Cranial Maxillofac Trauma Reconstruction DOI: 10.1055/s-0036-1597915In situ splitting of rib bone graft was conducted in 22 patients for the repair of orbital fracture with no other complicating fractures. A bone graft was harvested from the sixth or seventh rib in the right side. The repair of the orbital floor and medial wall was successful in all the cases. Ten patients had bone grafting to the orbital floor, eight had it done onto medial wall, and 4 onto both floor and wall after reduction. The mean length of in situ rib bone graft was 40.9 mm (range, 20–70 mm), the mean width of these was 14.9 mm (range, 8–20 mm). The bone grafting was done by one leaf for 15 cases and two leafs for 7 cases in size of defects. The technique of in situ splitting of a rib bone graft for the repair of the orbital floor and medial wall is a simple and safe procedure, easily taking out the in situ splitting of a rib, and less pain in donor site. It has proved to be an optimal choice in craniofacial reconstruction, especially the defects of orbital floor and medial wall. [...] Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.Article in Thieme eJournals: Table of contents  |  Abstract  |  Full text
Source: Craniomaxillofacial Trauma and Reconstruction - Category: ENT & OMF Authors: Tags: Original Article Source Type: research