Whole Arm Water Displacement Volumetry Is a Reliable and Sensitive Measure: A Pilot to Assess Acute Postburn Volume Change

This study aimed to confirm the reliability and investigate the impact of time between repeated trials on the sensitivity of WDV as a measure of whole UL volume change in an uninjured cohort and a burn injured pilot group. Within session, duplicate measures of whole UL WDV were recorded in two groups of noninjured volunteers and a group of burn patients. Each noninjured group differed only in the time between WDV repeats. The reliability trials were performed 50 ml for noninjured and>100 ml for burn patients. Despite this, a systematic bias was demonstrated between the T10 group means. The T20 group trials did not indicate such error on statistical testing (P = .297). The study confirms that WDV measurement of whole ULs is reliable and sensitive, if used at least 20 minutes apart. However, a significant and clinically relevant subject-by-method interaction was demonstrated. Researchers and clinicians are reminded to be aware of the performance of the technique when designing investigations in patient populations.
Source: Journal of Burn Care and Research - Category: Rehabilitation Tags: Original Articles Source Type: research
More News: Burns | Lymphedema | Statistics | Study