ENVIRONMENTAL DOSIMETRY WITH THE BeOSL PERSONAL DOSEMETER

In the course of this work, a dosemeter for measurement of ambient dose equivalent H*(10) based on the BeOSL dosimetry system was designed. Calculations of the energy response of the two-element BeOSL personal dosemeter in terms of H*(10) showed that the response does not fulfil the requirements of IEC 62387. Especially, the response for photon energies of 60–100 keV is too low. It is possible to correct this under-response using a BeOSL two-element dosemeter, a linear algorithm and an additional cover for the dosemeter. The Hp(0.07) element is shielded with lead, and with the help of a linear algorithm, corrections of the energy response are possible. So, the national requirements for an H*(10) area dosemeter in Germany can be fulfilled. The requirements of IEC 62387 are fulfilled for angles of radiation incidence from 0° to 60° for a rotation around the vertical and horizontal axis through the dosemeter, whereas for angles of incidence from 75° to 90°, the requirements are only fulfilled for rotation around the vertical axis through both elements.