Orbital Adherence Syndrome following the Use of Titanium Precontoured Orbital Mesh for the Reconstruction of Posttraumatic Orbital Floor Defects

We present two cases of orbital adherence syndrome following the use of titanium mesh for orbital floor reconstruction. In both cases, we also delineate the management of this syndrome. Our first patient reported good recovery after surgical intervention to relieve the tethering to the titanium mesh and subsequent placement of a smooth interface implant. The other patient was managed nonsurgically with resolution of symptoms. We highlight possible signs that might suggest the need for early surgical intervention. Orbital adherence syndrome is a poorly described and understood phenomenon and appears to occur after the use of large-pored titanium mesh for orbital reconstruction. Prevention is possible through careful patient selection and the placement of a smooth interface medium in the initial surgery.[...]Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.Article in Thieme eJournals:Table of contents  |  Abstract  |  Full text
Source: Craniomaxillofacial Trauma and Reconstruction - Category: ENT & OMF Authors: Tags: Case Report Source Type: research