Measurement outcomes from hip simulators

In this study, hard-on-hard (CoCr alloy, AgCrN coating) and hard-on-soft (CoCr alloy and CrN coating on vitamin E blended highly cross-linked polyethylene) bearing combinations were tested in an orbital hip simulator under standard and some adverse conditions. Gravimetric wear rates were determined for all bearings, with cobalt and where applicable, silver release determined throughout testing. Isolation of wear particles from the lubricating fluid was used to determine the influence of different bearing combinations and wear conditions on particle morphology. It was found that cobalt and silver could be measured in the lubricating fluid even when volumetric wear was not detectable. In hard-on-hard bearings, Pearson’s correlation of 0.98 was established between metal release into the lubricating fluid and wear volume. In hard-on-soft bearings, coating the head did not influence the polyethylene wear rates measured under standard conditions but did influence the cobalt release; the diameter influenced both polyethylene wear and cobalt release, and the introduction of adverse testing generated smaller polyethylene particles. While hip simulators can be useful to assess the wear performance of a new material or design, measurement of other outcomes may yield greater insight into the clinical behaviour of the bearings in vivo.
Source: Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine - Category: Biomedical Engineering Authors: Tags: Special Issue Articles Source Type: research