Potential of fibre optic daylighting systems in tropical Malaysia

This study examines the illumination levels obtained using a fibre optic daylighting system under various tropical climate conditions in Malaysia. A Parans SP3 fibre optic daylighting system with 10-m cable was used on a full-scale test bed model in Universiti Sains Malaysia as an empirical approach. The following results were obtained: (i) on sunny days with intermediate blue sky, the system worked at 79% and reached a maximum of 725 lx, an average of 457 lx, and a minimum of 98 lx; (ii) on moderately sunny days with intermediate mean sky, the system worked at 48.5% and reached a maximum 685 lx, an average of 439 lx, and a minimum of 80 lx; (iii) under overcast skies, the system worked at 37.5% and reached a maximum of 538 lx, an average of 305 lx, and a minimum of 41 lx. These findings provide benchmarking directions for the application of fibre optic daylighting systems in Malaysia.
Source: Indoor and Built Environment - Category: Occupational Health Authors: Tags: Original Papers Source Type: research