Small Bowel Dose Tolerance for Stereotactic Body Radiation Therapy

Inconsistencies permeate the literature regarding small bowel dose tolerance limits for stereotactic body radiation therapy (SBRT) treatments. In this review, we organized these diverse published limits with MD Anderson at Cooper data into a unified framework, constructing the dose-volume histogram (DVH) Risk Map, demonstrating low-risk and high-risk SBRT dose tolerance limits for small bowel. Statistical models of clinical data from 2 institutions were used to assess the safety spectrum of doses used in the exposure of the gastrointestinal tract in SBRT; 30% of the analyzed cases had vascular endothelial growth factor inhibitors (VEGFI) or other biological agents within 2 years before or after SBRT.
Source: Seminars in Radiation Oncology - Category: Cancer & Oncology Authors: Source Type: research