Common Iliac Artery Aneurysm Repair Using a Sac-Anchoring Endograft to Preserve the Internal Iliac Artery

Conclusion: Endovascular sealing using the Nellix device can be applied to exclude selected common iliac artery aneurysms with an adequate length and a minimal distal neck, with preservation of the internal iliac artery. The endobag can be positioned such that the aneurysm is completely excluded while the orifice of the side branch is not endangered.
Source: Journal of Endovascular Therapy - Category: Surgery Authors: Tags: Endovascular Aneurysm Sealing Source Type: research