Reduction in Central Line-Associated Bloodstream Infection Rates After Implementations of Infection Control Measures at a Level 3 Neonatal Intensive Care Unit

The objective was to decrease CLABSIs using evidence-based measures. The retrospective review compared CLABSI incidence during and after changes in catheter care. In April 2011, intravenous (IV) tubing changed from Interlink to Clearlink; IV tubing changing interval increased from 24 to 72 hours. CLABSIs increased. The following measures were implemented: July 2011, reeducation of neonatal intensive care staff on Clearlink; August 2011, IV tubing changing interval returned to 24 hours; September 2011, changed from Clearlink back to Interlink; November 2011, review of entire IV process and in-service on hand hygiene; December 2011, competencies on IV access for all nurses. CLABSIs were compared during and after interventions. Means were compared using the t test and ratios using the 2 test; P <.05. CLABSIs decreased from 4.4/1000 to 0/1000 catheter-days; P < .05. Evidence-based interventions reduced CLABSIs.
Source: American Journal of Medical Quality - Category: Health Management Authors: Tags: Articles Source Type: research