Vascular response to bioresorbable polymer sirolimus-eluting stent vs. permanent polymer everolimus-eluting stent at 9-month follow-up: an optical coherence tomography sub-study from the CENTURY II trial

Conclusion BP-SES shows an excellent vascular healing response at 9-month follow-up, which is similar to PP-EES.
Source: European Journal of Echocardiography - Category: Cardiology Authors: Tags: ORIGINAL ARTICLES Source Type: research