Adnexectomy by poor man’s transvaginal NOTES

Abstract The purpose of this study was to demonstrate the feasibility and safety of adnexectomy by transvaginal natural orifice transluminal endoscopic surgery (vNOTES) for benign adnexal masses. Conventional, reusable laparoscopic instruments were used, inserted through aninexpensive, self-constructed single port device. Between November 2013 and November 2014, 20 adnexectomies by vNOTES were performed by a single surgeon (BJ). Only conventional, reusable laparoscopic instruments were used. The self-constructed single port device was made by assembling a surgical glove, a wound protector, one reusable 10-mm trocar, and four reusable 5-mm trocars. The adnexectomy was performed according to the technique for standard laparoscopic surgery, and the specimen was removed through the colpotomy incision. Patient and perioperative data were analysed. Twenty patients underwent adnexectomy by vNOTES, and no conversion to standard laparoscopy or laparotomy was necessary. Mean operation time was 32 min (20–50 min); mean drop in hemoglobin level was 0.9 g/dl (0–2.1 g/dl). There were no operative complications. Post-operative pain scores were very low. The mean size of the removed adnexal mass was 51.8 mm (35–110 mm). Adnexectomy by vNOTES is feasible even for masses up to 110 mm and even when performed with reusable, conventional laparoscopic instruments. The main advantages of vNOTES are better cosmetics, low postoperative pain scores and easy removal of th...
Source: Gynecological Surgery - Category: OBGYN Source Type: research